FiCR: Fire Compliance and Risk Analysis Ontology
language en

FiCR: Fire Compliance and Risk Analysis Ontology

Modified on: 2025-07-01
This version:
https://w3id.org/ficr/1.1.0
Revision:
1.1.0
Issued on:
2025-06-26
Authors:
Yu Zhang
Dayou Chen
Long Chen
Imported Ontologies:
bot#
Download serialization:
JSON-LD RDF/XML N-Triples TTL
License:
https://creativecommons.org/licenses/by/4.0/
Visualization:
Visualize with WebVowl
Cite as:
Yu Zhang, Dayou Chen, Long Chen. FiCR: Fire Compliance and Risk Analysis Ontology. Revision: 1.1.0. Retrieved from: https://w3id.org/ficr/1.1.0
Provenance of this page
Ontology Specification Draft

FiCR: Fire Compliance and Risk Analysis Ontology: Overview back to ToC

This ontology has the following classes and properties.

Classes

Object Properties

Data Properties

Annotation Properties

Named Individuals

FiCR: Fire Compliance and Risk Analysis Ontology: Description back to ToC

Property domain convention: properties shared by multiple record types (e.g. supportedByEvidence, hasEvidenceStatus, measurement properties such as hasActualREI) are deliberately declared without rdfs:domain to avoid unintended type inference. Properties with a single host class declare an explicit rdfs:domain. Intended subjects are documented in each property's rdfs:comment.

Cross-reference for FiCR: Fire Compliance and Risk Analysis Ontology classes, object properties and data properties back to ToC

This section provides details for each class and property defined by FiCR: Fire Compliance and Risk Analysis Ontology.

Classes

AccessRoomRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#AccessRoomRole

has super-classes
EscapeAndEvacuationRole c
has members
AccessRoomRole ni
is also defined as
named individual

Accommodationc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Accommodation

has super-classes
UtilizationPurpose c
has members
Accommodation ni
is also defined as
named individual

ActiveFireProtectionRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ActiveFireProtectionRole

has super-classes
FireProtectionRole c
has members
ActiveFireProtectionRole ni
is also defined as
named individual

Alarmc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Alarm

An individual fire alarm equipment item or device that provides warning functionality within a fire alarm or detection arrangement. This class represents equipment-level alarm items.
has super-classes
FireProtectionEquipment c
is in domain of
hasCoverageType dp, hasDetectionType dp

AlternativeEscapeRouteRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#AlternativeEscapeRouteRole

has super-classes
EscapeAndEvacuationRole c
has members
AlternativeEscapeRouteRole ni
is also defined as
named individual

AlternativeExitRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#AlternativeExitRole

has super-classes
EscapeAndEvacuationRole c
has members
AlternativeExitRole ni
is also defined as
named individual

AnomalyTriggerEventc back to ToC or Class ToC

IRI: https://w3id.org/ficr#AnomalyTriggerEvent

A trigger event generated when abnormal conditions are detected by monitoring or analytics, causing tasks to be created for verification, inspection, or risk follow-up.
has super-classes
Event c

ApplianceVentilationDuctc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ApplianceVentilationDuct

A duct to deliver combustion air to a gas appliance.
has super-classes
HVACSystem c

ApplicabilityStatec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ApplicabilityState

A controlled state indicating whether a requirement, rule, or assessment condition applies in a given context.
has super-classes
AssessmentState c
has sub-classes
Applicable c, NotApplicable c, NotAssessed c
is in range of
hasApplicabilityState op

Applicablec back to ToC or Class ToC

IRI: https://w3id.org/ficr#Applicable

has super-classes
ApplicabilityState c
has members
Applicable ni
is disjoint with
NotApplicable c, NotAssessed c
is also defined as
named individual

AssemblyPlacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#AssemblyPlace

has super-classes
UtilizationPurpose c
has members
AssemblyPlace ni
is also defined as
named individual

Assessmentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Assessment

A fire-related assessment record produced through an O&M task. It may represent compliance checking, risk analysis, or inspection assessment and can produce assessment findings.
has sub-classes
ComplianceChecking c, InspectionAssessment c, RiskAnalysis c
is in domain of
assessesElement op, assessesZone op, hasAssessmentBasis op, producesFinding op, reliesOnBoundaryCondition op
is in range of
producesAssessment op

AssessmentBasisc back to ToC or Class ToC

IRI: https://w3id.org/ficr#AssessmentBasis

A bundle of evidence items used to justify a fire compliance evaluation or risk assessment. It groups observed site evidence, regulatory sources, and supporting external documents for traceability and explanation.
has sub-classes
EvidenceItem c, RegulatorySource c
is in domain of
documentTitle dp, documentURI dp
is in range of
hasAssessmentBasis op

AssessmentFindingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#AssessmentFinding

A record produced by an assessment to capture a compliance, risk, or inspection finding concerning an assessed element, system, zone, risk unit, requirement, or scenario. Findings may be linked to evidence, evidence status, and assessment results where applicable.
has sub-classes
ComplianceFinding c, InspectionFinding c, RiskFinding c
is in domain of
concernsElement op, concernsRiskUnit op, concernsSystem op, concernsZone op, hasApplicabilityState op, hasFindingStatement dp
is in range of
producesFinding op

AssessmentStatec back to ToC or Class ToC

IRI: https://w3id.org/ficr#AssessmentState

An abstract superclass for controlled state or result values used in FiCR assessments, including boundary condition states, operational impairment states, evidence states, applicability states, and compliance results. Subclasses retain their domain-specific meanings and are not merged.
has sub-classes
ApplicabilityState c, ComplianceResult c, ConditionState c, EvidenceStatus c, ImpairmentState c, InstallationStatus c

AtriumSpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#AtriumSpace

A continuous space that passes through one or more structural floors within a building, not necessarily vertically. Enclosed lift wells, enclosed escalator wells, building services ducts and stairs are not classified as atria.
has super-classes
Space c
is disjoint with
BalconySpace c, CavitySpace c, DuctSpace c, RoofSpace c, RoomSpace c, ShaftSpace c, StairSpace c

Auditoriumc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Auditorium

has super-classes
SpaceUsage c
has members
Auditorium ni
is disjoint with
Bathroom c, CirculationUsage c, Gallery c, HabitableRoom c, Kitchen c, PlaceOfSpecialHazard c, ServiceUsage c, Warehouse c
is also defined as
named individual

AutomaticReleaseMechanismc back to ToC or Class ToC

IRI: https://w3id.org/ficr#AutomaticReleaseMechanism

A device that normally holds a door open, but closes it automatically if any one of the following occurs. • Smoke is detected by an automatic device of a suitable nature and quality in a suitable location. • A hand-operated switch, fitted in a suitable position, is operated. • The electricity supply to the device, apparatus or switch fails. • The fire alarm system, if any, is operated.
has super-classes
FireProtectionEquipment c

BalconySpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#BalconySpace

A balcony is a platform projecting from the wall of a building, enclosed by a balustrade or railing, and accessed from an upper-level room.
has super-classes
Space c
is disjoint with
AtriumSpace c, CavitySpace c, DuctSpace c, RoofSpace c, RoomSpace c, ShaftSpace c, StairSpace c

BasementStoreyc back to ToC or Class ToC

IRI: https://w3id.org/ficr#BasementStorey

A storey with a floor that, at some point, is more than 1200mm below the highest level of ground beside the outside walls. (However, see Appendix B, paragraph B26c, for situations where the storey is considered to be a basement only because of a sloping site.)
is equivalent to
Storey c and (isAboveGround dp value false)
has super-classes
Storey c
is disjoint with
GroundAndAboveStorey c

Bathroomc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Bathroom

has super-classes
SpaceUsage c
has members
Bathroom ni
is disjoint with
Auditorium c, CirculationUsage c, Gallery c, HabitableRoom c, Kitchen c, PlaceOfSpecialHazard c, ServiceUsage c, Warehouse c
is also defined as
named individual

Beamc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Beam

A beam is a horizontal structural element that carries loads perpendicular to its length, transferring weight from a roof, floor, or ceiling to vertical supports like columns or walls.
has super-classes
StructuralElement c

BoardingHousec back to ToC or Class ToC

IRI: https://w3id.org/ficr#BoardingHouse

has super-classes
UtilizationPurpose c
has members
BoardingHouse ni
is also defined as
named individual

BoilerRoomc back to ToC or Class ToC

IRI: https://w3id.org/ficr#BoilerRoom

has super-classes
PlaceOfSpecialHazard c
has members
BoilerRoom ni
is disjoint with
EngineRoom c, FuelStorage c, SwitchGearRoom c, TransformerRoom c
is also defined as
named individual

BoundaryAssumptionc back to ToC or Class ToC

IRI: https://w3id.org/ficr#BoundaryAssumption

A boundary condition record used where risk analysis relies on an assumed, incomplete, or provisionally assessed boundary-performance condition. It may later be confirmed, revised, or replaced by inspection evidence.
has super-classes
BoundaryConditionRecord c

BoundaryConditionRecordc back to ToC or Class ToC

IRI: https://w3id.org/ficr#BoundaryConditionRecord

A record describing the assessed or assumed condition of a fire-related boundary or boundary-performance aspect within a risk unit. It may be used as an assessment dependency and can be linked to condition state, evidence status, supporting evidence, and related physical elements.
has sub-classes
BoundaryAssumption c
is in domain of
aboutElement op, appliesToRiskUnit op, hasBoundaryPerformanceAspect op, hasConditionState op
is in range of
dependsOnBoundaryCondition op, reliesOnBoundaryCondition op

BoundaryPerformanceAspectc back to ToC or Class ToC

IRI: https://w3id.org/ficr#BoundaryPerformanceAspect

A classification of the boundary-related performance aspect considered in fire risk interpretation, such as compartmentation, cavity barrier performance, external fire spread, or structural stability.
has sub-classes
CavityBarrierPerformanceAspect c, CompartmentationPerformanceAspect c, ExternalFireSpreadPerformanceAspect c, StructuralStabilityPerformanceAspect c
is in range of
hasBoundaryPerformanceAspect op

BuildingContentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#BuildingContent

A movable or non-integral physical object relevant to fire assessment, such as furniture, finishes, or contents.
has super-classes
Building element c, PhysicalObject c
has sub-classes
Finishes c, Furnishings c

BuildingSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#BuildingSystem

A building system refers to the interconnected, functional components of a building, including its mechanical, and electrical infrastructure.
has sub-classes
ElectricalSystem c, EmergencyLightingSystem c, FireProtectionSystem c, HVACSystem c, PipingSystem c, VerticalTransportSystem c
is in domain of
hasComponent op, hasSystemFireSafetyRole op, isSystemContainedIn op
is in range of
concernsSystem op, containsSystem op

CarParkingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#CarParking

has super-classes
UtilizationPurpose c
has members
CarParking ni
is also defined as
named individual

CavityBarrierc back to ToC or Class ToC

IRI: https://w3id.org/ficr#CavityBarrier

A construction within a cavity, other than a smoke curtain, to perform either of the following functions. • Close a cavity to stop smoke or flame entering. • Restrict the movement of smoke or flame within a cavity.
has super-classes
FabricElement c, FireProtectionElement c

CavityBarrierPerformanceAspectc back to ToC or Class ToC

IRI: https://w3id.org/ficr#CavityBarrierPerformanceAspect

has super-classes
BoundaryPerformanceAspect c
has members
CavityBarrierPerformanceAspect ni
is also defined as
named individual

CavitySpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#CavitySpace

A space enclosed by elements of a building (including a suspended ceiling) or contained within an element, but that is not a room, cupboard, circulation space, protected shaft, or space within a flue, chute, duct, pipe or conduit.
has super-classes
Space c
is disjoint with
AtriumSpace c, BalconySpace c, DuctSpace c, RoofSpace c, RoomSpace c, ShaftSpace c, StairSpace c

Ceilingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Ceiling

Part of a building that encloses a room, protected shaft or circulation space and is exposed overhead. The soffit of a rooflight, but not the frame, is included as part of the surface of the ceiling. An upstand below a rooflight is considered as a wall.
has super-classes
FabricElement c

CertificateEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#CertificateEvidence

A document evidence item representing a certificate that supports an assessment finding or record.
has super-classes
DocumentEvidence c

Circuitc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Circuit

A continuous pathway that allows electricity to flow from the main supply (consumer unit) to various outlets, lights, or appliances, and back again.
has super-classes
ElectricalSystem c

CirculationSpaceRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#CirculationSpaceRole

has super-classes
EscapeAndEvacuationRole c
has members
CirculationSpaceRole ni
is also defined as
named individual

CirculationUsagec back to ToC or Class ToC

IRI: https://w3id.org/ficr#CirculationUsage

has super-classes
SpaceUsage c
has sub-classes
Corridor c, EntranceHall c, Foyer c, Hall c, Lobby c
has members
CirculationUsage ni
is disjoint with
Auditorium c, Bathroom c, Gallery c, HabitableRoom c, Kitchen c, PlaceOfSpecialHazard c, ServiceUsage c, Warehouse c
is also defined as
named individual

Claddingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Cladding

Cladding is an external layer applied to a building's structure to provide weather protection, thermal insulation, and improved aesthetics.
has super-classes
ExternalWall c

Classificationc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Classification

Classify buildings or compartments according to their intended use, construction type, or structural risk to ensure safety, regulatory compliance, and facilitate communication between professionals such as planners, insurers, and contractors.
has sub-classes
RegulatoryClassification c

Closingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Closing

A fabric element category for components that close openings in the building envelope or internal partitions, including doors, windows, and dampers.
has super-classes
FabricElement c
has sub-classes
Doorset c, FireDamper c, Rooflight c, SelfClosingDevice c, Window c

Columnc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Column

A column is a vertical structural element in a building that supports loads from above and transfers them down to the foundation.
has super-classes
StructuralElement c

CommercialPlacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#CommercialPlace

has super-classes
UtilizationPurpose c
has members
CommercialPlace ni
is also defined as
named individual

CompartmentationPerformanceAspectc back to ToC or Class ToC

IRI: https://w3id.org/ficr#CompartmentationPerformanceAspect

has super-classes
BoundaryPerformanceAspect c
has members
CompartmentationPerformanceAspect ni
is also defined as
named individual

CompartmentFloorc back to ToC or Class ToC

IRI: https://w3id.org/ficr#CompartmentFloor

A fire resisting floor to separate one fire compartment from another.
is equivalent to
Floor c and (hasPhysicalObjectFireSafetyRole op some FireSeparatingRole c)
has super-classes
FireProtectionElement c, Floor c

CompartmentWallc back to ToC or Class ToC

IRI: https://w3id.org/ficr#CompartmentWall

A fire resisting wall to separate one fire compartment from another. including a wall that is common to two or more buildings.
is equivalent to
Wall c and (hasPhysicalObjectFireSafetyRole op some FireSeparatingRole c)
has super-classes
FireProtectionElement c, Wall c

ComplianceCheckingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ComplianceChecking

An assessment that checks whether fire-related requirements are satisfied. It produces compliance findings rather than storing a single assessment-level result.
has super-classes
Assessment c

ComplianceCheckingTaskc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ComplianceCheckingTask

A task that evaluates one or more requirements against available evidence and produces a compliance result.
has super-classes
Task c

ComplianceFindingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ComplianceFinding

An assessment finding produced by compliance checking. It records the assessed item, applicable requirement, actual value or condition, required value or criterion, compliance result, evidence status, and regulatory basis where available.
has super-classes
AssessmentFinding c
is in domain of
checksRequirement op, hasComplianceResult op
is in range of
usesComplianceFinding op
is disjoint with
InspectionFinding c, RiskFinding c

ComplianceRequestTriggerEventc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ComplianceRequestTriggerEvent

A trigger event created when a compliance request is received from an external authority, or when a prior task identifies missing evidence or unmet preconditions requiring follow-up inspection or assessment.
has super-classes
Event c

ComplianceResultc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ComplianceResult

A controlled assessment state representing the result of a compliance finding, such as compliant, non-compliant, or undetermined. Compliance results are attached to ComplianceFinding records so that they remain traceable to the assessed target, checked requirement, evidence status, and regulatory source.
has super-classes
AssessmentState c
has sub-classes
CompliantResult c, NonCompliantResult c, UndeterminedResult c
is in range of
hasComplianceResult op

CompliantResultc back to ToC or Class ToC

IRI: https://w3id.org/ficr#CompliantResult

has super-classes
ComplianceResult c
has members
CompliantResult ni
is disjoint with
NonCompliantResult c, UndeterminedResult c
is also defined as
named individual

Compromisedc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Compromised

has super-classes
ConditionState c
has members
Compromised ni
is disjoint with
Effective c, Unknown c
is also defined as
named individual

ConditionStatec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ConditionState

Physical performance status assessment of boundary condition state.
has super-classes
AssessmentState c
has sub-classes
Compromised c, Effective c, Unknown c
is in range of
hasConditionState op

Controllerc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Controller

In buildings, a "controller" is the "brain" of an automated system, receiving data from sensors and sending commands to devices like HVAC, lighting, and alarms to ensure comfort and efficiency.
has super-classes
Equipment c

Corridorc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Corridor

has super-classes
CirculationUsage c
has members
Corridor ni
is disjoint with
EntranceHall c, Foyer c, Hall c, Lobby c
is also defined as
named individual

Curtainc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Curtain

Part of a solar shading device which is set in motion by the operating system and fulfils the purpose of a blind, awning or shutter.
has super-classes
FabricElement c

DeadEndRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#DeadEndRole

has super-classes
EscapeAndEvacuationRole c
has members
DeadEndRole ni
is also defined as
named individual

DeficiencyFindingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#DeficiencyFinding

An inspection finding that records an observed defect, shortfall, obstruction, damage, missing evidence, or other adverse condition relevant to fire-related O&M assessment.
has super-classes
InspectionFinding c

DetentionHousec back to ToC or Class ToC

IRI: https://w3id.org/ficr#DetentionHouse

has super-classes
UtilizationPurpose c
has members
DetentionHouse ni
is also defined as
named individual

DocumentEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#DocumentEvidence

An external file or record that supports assessment or documentation, such as product data sheets, installation manuals, certificates, drawings, or inspection reports. It is linked for human access and traceability and does not directly participate in logical inference unless explicitly modelled.
has super-classes
EvidenceItem c
has sub-classes
CertificateEvidence c, DrawingEvidence c, InspectionReportEvidence c, MaintenanceRecordEvidence c, PhotographEvidence c

Doorsetc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Doorset

A doorset is a complete, integrated door system consisting of the door leaf, frame, and all necessary hardware like hinges, seals, and closers, sold as a single unit from one source.
has super-classes
Closing c
has sub-classes
ExternalWallDoor c, FireDoorset c

DrawingEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#DrawingEvidence

A document evidence item representing a drawing that supports an assessment finding or record.
has super-classes
DocumentEvidence c

DuctSpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#DuctSpace

A duct space is a designated area or channel within a building that houses the systems for conveying air, cables, and other utilities.
has super-classes
Space c
is disjoint with
AtriumSpace c, BalconySpace c, CavitySpace c, RoofSpace c, RoomSpace c, ShaftSpace c, StairSpace c

Dwellinghousec back to ToC or Class ToC

IRI: https://w3id.org/ficr#Dwellinghouse

has super-classes
UtilizationPurpose c
has members
Dwellinghouse ni
is also defined as
named individual

Effectivec back to ToC or Class ToC

IRI: https://w3id.org/ficr#Effective

has super-classes
ConditionState c
has members
Effective ni
is disjoint with
Compromised c, Unknown c
is also defined as
named individual

ElectricalSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ElectricalSystem

An electrical system in a building is a network of wiring, equipment, and protective devices that safely distributes power from its entry point to all the loads, such as lights, outlets, and appliances, within the structure.
has super-classes
BuildingSystem c
has sub-classes
Circuit c

EmergencyLightingSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EmergencyLightingSystem

A protection system that provides lighting for escape routes, safety equipment, or relevant spaces when normal lighting fails.
has super-classes
BuildingSystem c
has sub-classes
EscapeLighting c

EngineRoomc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EngineRoom

has super-classes
PlaceOfSpecialHazard c
has members
EngineRoom ni
is disjoint with
BoilerRoom c, FuelStorage c, SwitchGearRoom c, TransformerRoom c
is also defined as
named individual

EntertainmentPlacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#EntertainmentPlace

has super-classes
UtilizationPurpose c
has members
EntertainmentPlace ni
is also defined as
named individual

EntranceHallc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EntranceHall

has super-classes
CirculationUsage c
has members
EntranceHall ni
is disjoint with
Corridor c, Foyer c, Hall c, Lobby c
is also defined as
named individual

Equipmentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Equipment

An independently identifiable and maintainable physical device or apparatus. Equipment is modelled as ficr:PhysicalObject and aligned with bot:Element when it is located in or associated with the building topology.
has super-classes
Building element c, PhysicalObject c
has sub-classes
Controller c, FireProtectionEquipment c, Sensor c
is in domain of
hasServiceExpiryDate dp

EquipmentInspectionTaskc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EquipmentInspectionTask

Inspection task consumes observations produced by upstream tools.
has super-classes
Task c

EscapeAndEvacuationRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#EscapeAndEvacuationRole

A fire safety role related to escape, evacuation, exits, access rooms, protected routes, dead ends, circulation spaces, or other route-related fire-safety interpretation.
has super-classes
FireSafetyRole c
has sub-classes
AccessRoomRole c, AlternativeEscapeRouteRole c, AlternativeExitRole c, CirculationSpaceRole c, DeadEndRole c, EvacuationRole c, ExitPassagewayRole c, FinalExitRole c, InnerRoomRole c, MeansOfEscapeRole c, StoreyExitRole c

EscapeLightingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EscapeLighting

The part of the emergency lighting that is provided to ensure that the escape route is illuminated at all material times.
has super-classes
EmergencyLightingSystem c

EvacuationLiftc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvacuationLift

A lift that may be used to evacuate people in a fire.
is equivalent to
LiftSystem c and (hasSystemFireSafetyRole op some EvacuationRole c)
has super-classes
FireProtectionSystem c

EvacuationRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvacuationRole

has super-classes
EscapeAndEvacuationRole c
has members
EvacuationRole ni
is also defined as
named individual

Eventc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Event

An occurrence that triggers the creation of one or more tasks in the FiCR workflow, such as a routine schedule, an anomaly alert, or a compliance request.
has sub-classes
AnomalyTriggerEvent c, ComplianceRequestTriggerEvent c, RoutineTriggerEvent c
is in domain of
triggersTask op
is in range of
triggeredBy op

EvidenceAvailablec back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvidenceAvailable

has super-classes
EvidenceStatus c
has members
EvidenceAvailable ni
is disjoint with
EvidenceInsufficient c, EvidenceMissing c, EvidenceNotRequired c
is also defined as
named individual

EvidenceInsufficientc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvidenceInsufficient

has super-classes
EvidenceStatus c
has members
EvidenceInsufficient ni
is disjoint with
EvidenceAvailable c, EvidenceMissing c, EvidenceNotRequired c
is also defined as
named individual

EvidenceItemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvidenceItem

A single piece of evidence that supports an assessment. It may be an observation, a regulatory reference, or an external document. Evidence items are linkable, traceable, and can be attached to specific assets, spaces, or checks.
has super-classes
AssessmentBasis c
has sub-classes
DocumentEvidence c, ObservedEvidence c, SensorEvidence c, TestEvidence c
is in range of
producesEvidence op, supportedByEvidence op, usesEvidence op

EvidenceMissingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvidenceMissing

has super-classes
EvidenceStatus c
has members
EvidenceMissing ni
is disjoint with
EvidenceAvailable c, EvidenceInsufficient c, EvidenceNotRequired c
is also defined as
named individual

EvidenceNotRequiredc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvidenceNotRequired

has super-classes
EvidenceStatus c
has members
EvidenceNotRequired ni
is disjoint with
EvidenceAvailable c, EvidenceInsufficient c, EvidenceMissing c
is also defined as
named individual

EvidenceStatusc back to ToC or Class ToC

IRI: https://w3id.org/ficr#EvidenceStatus

A controlled assessment state describing whether the evidence required to support an assessment finding or boundary condition record is available, missing, insufficient, or not required.
has super-classes
AssessmentState c
has sub-classes
EvidenceAvailable c, EvidenceInsufficient c, EvidenceMissing c, EvidenceNotRequired c
is in range of
hasEvidenceStatus op

ExitPassagewayRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ExitPassagewayRole

has super-classes
EscapeAndEvacuationRole c
has members
ExitPassagewayRole ni
is also defined as
named individual

ExternalFireSpreadPerformanceAspectc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ExternalFireSpreadPerformanceAspect

has super-classes
BoundaryPerformanceAspect c
has members
ExternalFireSpreadPerformanceAspect ni
is also defined as
named individual

ExternalWallc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ExternalWall

The external wall of a building includes all of the following. • Anything located within any space forming part of the wall. • Any decoration or other finish applied to any external (but not internal) surface forming part of the wall. • Any windows and doors in the wall. • Any part of a roof pitched at an angle of more than 70 degrees to the horizontal if that part of the roof adjoins a space within the building to which persons have access, but not access only for the purpose of carrying out repairs or maintenance.
is equivalent to
Wall c and (isExternal dp value true)
has super-classes
Wall c
has sub-classes
Cladding c

ExternalWallDoorc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ExternalWallDoor

An external wall door is a door that is part of a building's exterior wall, providing an entrance and exit to the building.
is equivalent to
Doorset c and (isExternal dp value true)
has super-classes
Doorset c

ExternalWallWindowc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ExternalWallWindow

An external wall window is a window that is part of a building's exterior wall, which acts as the outer boundary separating the interior from the outside environment.
is equivalent to
Window c and (isExternal dp value true)
has super-classes
Window c

FabricElementc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FabricElement

A physical construction element forming part of the building fabric. Fabric elements are modelled as ficr:PhysicalObject and aligned with bot:Element so that they can participate in spatial containment, adjacency, and fire-related classification.
has super-classes
Building element c, PhysicalObject c
has sub-classes
CavityBarrier c, Ceiling c, Closing c, Curtain c, FireStop c, Floor c, Opening c, Railing c, Roof c, SpecifiedAttachment c, Stair c, StairFlight c, StructuralElement c

Factoryc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Factory

has super-classes
UtilizationPurpose c
has members
Factory ni
is also defined as
named individual

FinalExitRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FinalExitRole

has super-classes
EscapeAndEvacuationRole c
has members
FinalExitRole ni
is also defined as
named individual

Finishesc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Finishes

Finishes are the final surface treatments and decorative elements applied to a building's interior and exterior.
has super-classes
BuildingContent c

FireAlarmSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireAlarmSystem

A system-level arrangement of components for detecting fire and giving audible, visual, or other perceptible warning of fire.
has super-classes
FireProtectionSystem c

FireAndSmokeDamperc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireAndSmokeDamper

A fire damper which, in addition to the performance of the fire damper, resists the spread of smoke.
has super-classes
FireDamper c

FireCompartmentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireCompartment

A fire safety space bounded by compartment walls and compartment floors, designed to prevent the spread of fire and smoke beyond the compartment of origin.
is equivalent to
Zone c and (adjacent element op some CompartmentFloor c) and (adjacent element op some CompartmentWall c)
has super-classes
FireProtectionSpatialProvision c

FireDamperc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireDamper

A mechanical or intumescent device within a duct or ventilation opening that operates automatically and is designed to resist the spread of fire.
is equivalent to
Closing c and (hasPhysicalObjectFireSafetyRole op some FireResistingRole c)
has super-classes
Closing c, FireProtectionElement c
has sub-classes
FireAndSmokeDamper c

FireDoorsetc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireDoorset

A door or shutter which, together with its frame and furniture as installed in a building, is intended (when closed) to resist the spread of fire and/or gaseous products of combustion and meets specified performance criteria to those ends.
is equivalent to
Doorset c and ((hasPhysicalObjectFireSafetyRole op some FireResistingRole c) or (hasPhysicalObjectFireSafetyRole op some FireSeparatingRole c))
has super-classes
Doorset c, FireProtectionElement c

FireExtinguisherc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireExtinguisher

A portable or fixed manually-operated device containing an extinguishing agent that can be expelled for the purpose of suppressing or extinguishing a fire. Fire extinguishers are classified by their agent type (water, foam, CO2, dry powder, wet chemical) and by the fire classes they are rated to address.
has super-classes
FireProtectionEquipment c
is in domain of
hasExtinguisherAgent dp, hasFireClassRating dp

FireFightingLiftc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireFightingLift

A lift with additional protection and with controls that enable it to be used by the fire and rescue service when fighting a fire.
is equivalent to
LiftSystem c and (hasSystemFireSafetyRole op some FirefightingRole c)
has super-classes
FireProtectionSystem c

FirefightingRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FirefightingRole

has super-classes
FirefightingSupportRole c
has members
FirefightingRole ni
is also defined as
named individual

FirefightingSupportRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FirefightingSupportRole

A fire safety role related to firefighter access, firefighting support, fire service intervention, or systems and spaces designated to support firefighting operations.
has super-classes
FireSafetyRole c
has sub-classes
FirefightingRole c

FireProtectionElementc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireProtectionElement

A physical object, building element, or component that contributes to fire protection performance. This class groups physical fire-protection provisions while preserving their identity through more specific classes such as wall, doorset, stair, damper, cavity barrier, or fire stop.
has super-classes
FireProtectionProvision c, PhysicalObject c
has sub-classes
CavityBarrier c, CompartmentFloor c, CompartmentWall c, FireDamper c, FireDoorset c, FireStop c, ProtectedStairway c

FireProtectionEquipmentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireProtectionEquipment

A maintainable equipment item that supports fire protection or fire safety operation, such as warning, detection, suppression, release, control, manual firefighting, monitoring, or activation. Equipment-level provisions remain distinct from system-level provisions.
has super-classes
Equipment c, FireProtectionProvision c
has sub-classes
Alarm c, AutomaticReleaseMechanism c, FireExtinguisher c

FireProtectionProvisionc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireProtectionProvision

A building element, equipment item, system, component, or spatial arrangement that is provided or designated to support fire protection or fire safety performance. This class is used as a common query target for fire-related provisions without treating all of them as building systems.
has sub-classes
FireProtectionElement c, FireProtectionEquipment c, FireProtectionSpatialProvision c, FireProtectionSystem c

FireProtectionRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireProtectionRole

A fire safety role related to active or passive fire protection, fire separation, fire resistance, or limitation of fire spread.
has super-classes
FireSafetyRole c
has sub-classes
ActiveFireProtectionRole c, FireResistingRole c, FireSeparatingRole c, PassiveFireProtectionRole c, UnprotectedAreaRole c

FireProtectionSpatialProvisionc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireProtectionSpatialProvision

A spatial zone or arrangement that contributes to fire protection or fire safety performance, such as a compartment, protected corridor, protected lobby, protected shaft, protected stairway space, or other protected escape or separation space.
has super-classes
FireProtectionProvision c, FireSafetySpace c
has sub-classes
FireCompartment c, ProtectedCorridor c, ProtectedEntranceHall c, ProtectedLobby c, ProtectedShaft c, ProtectedStairwaySpace c

FireProtectionSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireProtectionSystem

A distributed or system-level building system that supports fire protection or fire safety operation, including detection, alarm, suppression, smoke control, emergency lighting, protected electrical supply, firefighting support, or evacuation support.
has super-classes
BuildingSystem c, FireProtectionProvision c
has sub-classes
EvacuationLift c, FireAlarmSystem c, FireFightingLift c, FireSprinklerSystem c, ProtectedCircuit c

FireResistingRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireResistingRole

has super-classes
FireProtectionRole c
has members
FireResistingRole ni
is also defined as
named individual

FireRiskAssessmentTaskc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireRiskAssessmentTask

A task that produces a fire risk analysis assessment for O&M use. It supports risk-informed interpretation by linking risk units, fire risk scenarios, compliance findings, boundary condition records, condition states, and evidence status.
has super-classes
Task c

FireRiskScenarioc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireRiskScenario

A hypothetical fire scenario anchored to an origin space or zone. It describes the fire origin, relevant spread context, affected risk unit, and boundary conditions used for risk-informed O&M interpretation.
is in domain of
dependsOnBoundaryCondition op, hasOriginSpace op, hasScenarioDescription dp, hasScenarioRiskUnit op
is in range of
derivedFromScenario op, hasScenario op

FireSafetyRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireSafetyRole

A controlled role or designation assigned to a physical object, spatial zone, or building system to describe its fire-safety function. The role itself is independent of the assignment target; the assignment context is expressed by the property used, such as hasPhysicalObjectFireSafetyRole, hasZoneFireSafetyRole, or hasSystemFireSafetyRole.
has super-classes
UsageType c
has sub-classes
EscapeAndEvacuationRole c, FireProtectionRole c, FirefightingSupportRole c
is in range of
hasFireSafetyRole op, hasPhysicalObjectFireSafetyRole op, hasSystemFireSafetyRole op, hasZoneFireSafetyRole op, isFireSafetyRoleOf op

FireSafetySpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireSafetySpace

"Fire safety space" in a building refers to the areas designed to prevent the spread of fire and smoke and guide occupants to safety.
has super-classes
Zone c
has sub-classes
FireProtectionSpatialProvision c

FireSeparatingRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireSeparatingRole

has super-classes
FireProtectionRole c
has members
FireSeparatingRole ni
is also defined as
named individual

FireSprinklerSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireSprinklerSystem

A fire protection system that uses a network of pipes, control components, and sprinkler outlets to discharge water for fire suppression or control.
is equivalent to
PipingSystem c and (hasSystemFireSafetyRole op some ActiveFireProtectionRole c)
has super-classes
FireProtectionSystem c, PipingSystem c

FireStopc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FireStop

A seal provided to close an imperfection of fit or design tolerance between elements or components, to restrict the spread of fire and smoke.
has super-classes
FabricElement c, FireProtectionElement c

Flatc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Flat

has super-classes
UtilizationPurpose c
has members
Flat ni
is also defined as
named individual

Floorc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Floor

A floor is the horizontal surface in a building that forms the base of a room, providing structural support for occupants, furniture, and the building's own weight.
has super-classes
FabricElement c
has sub-classes
CompartmentFloor c, FloorSlab c

FloorSlabc back to ToC or Class ToC

IRI: https://w3id.org/ficr#FloorSlab

A horizontal structural slab forming an intermediate or ground-level floor, transferring occupancy and dead loads to the supporting structure.
has super-classes
Floor c, Slab c

Foyerc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Foyer

has super-classes
CirculationUsage c
has members
Foyer ni
is disjoint with
Corridor c, EntranceHall c, Hall c, Lobby c
is also defined as
named individual

FuelStoragec back to ToC or Class ToC

IRI: https://w3id.org/ficr#FuelStorage

has super-classes
PlaceOfSpecialHazard c
has members
FuelStorage ni
is disjoint with
BoilerRoom c, EngineRoom c, SwitchGearRoom c, TransformerRoom c
is also defined as
named individual

Furnishingsc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Furnishings

Movable items that make a space habitable and decorative.
has super-classes
BuildingContent c

GroundAndAboveStoreyc back to ToC or Class ToC

IRI: https://w3id.org/ficr#GroundAndAboveStorey

A storey at or above ground level, defined by isAboveGround = true.
is equivalent to
Storey c and (isAboveGround dp value true)
has super-classes
Storey c
is disjoint with
BasementStorey c

GuidanceDocumentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#GuidanceDocument

Guidance documents explaining how to meet requirements or how to conduct assessments are not necessarily laws in themselves.
has super-classes
RegulatorySource c
has members
A D B ni, B D M02 ni, Risk Evaluation Tool ni

HabitableRoomc back to ToC or Class ToC

IRI: https://w3id.org/ficr#HabitableRoom

has super-classes
SpaceUsage c
has members
HabitableRoom ni
is disjoint with
Auditorium c, Bathroom c, CirculationUsage c, Gallery c, Kitchen c, PlaceOfSpecialHazard c, ServiceUsage c, Warehouse c
is also defined as
named individual

Hallc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Hall

has super-classes
CirculationUsage c
has members
Hall ni
is disjoint with
Corridor c, EntranceHall c, Foyer c, Lobby c
is also defined as
named individual

HallOfResidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#HallOfResidence

has super-classes
UtilizationPurpose c
has members
HallOfResidence ni
is also defined as
named individual

Hospitalc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Hospital

has super-classes
UtilizationPurpose c
has members
Hospital ni
is also defined as
named individual

Hostelc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Hostel

has super-classes
UtilizationPurpose c
has members
Hostel ni
is also defined as
named individual

Hotelc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Hotel

has super-classes
UtilizationPurpose c
has members
Hotel ni
is also defined as
named individual

HVACSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#HVACSystem

An HVAC system is a building's climate control system for heating, ventilation, and air conditioning.
has super-classes
BuildingSystem c
has sub-classes
ApplianceVentilationDuct c

Impairedc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Impaired

has super-classes
ImpairmentState c
has members
Impaired ni
is disjoint with
ImpairmentUnknown c, Operational c
is also defined as
named individual

ImpairmentStatec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ImpairmentState

ImpairmentState of the building component.
has super-classes
AssessmentState c
has sub-classes
Impaired c, ImpairmentUnknown c, Operational c
is in range of
hasImpairmentState op

ImpairmentUnknownc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ImpairmentUnknown

has super-classes
ImpairmentState c
has members
ImpairmentUnknown ni
is disjoint with
Impaired c, Operational c
is also defined as
named individual

InnerRoomRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#InnerRoomRole

has super-classes
EscapeAndEvacuationRole c
has members
InnerRoomRole ni
is also defined as
named individual

InspectionAssessmentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#InspectionAssessment

An assessment activity that evaluates fire safety or compliance conditions through inspection.
has super-classes
Assessment c

InspectionFindingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#InspectionFinding

An assessment finding produced by inspection activity. It records observed fire-related conditions, deficiencies, evidence gaps, or verification outcomes relevant to O&M assessment.
has super-classes
AssessmentFinding c
has sub-classes
DeficiencyFinding c
is disjoint with
ComplianceFinding c, RiskFinding c

InspectionReportEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#InspectionReportEvidence

A document evidence item representing an inspection report that supports an assessment finding or record.
has super-classes
DocumentEvidence c

InstallationNotRequiredc back to ToC or Class ToC

IRI: https://w3id.org/ficr#InstallationNotRequired

has super-classes
InstallationStatus c
has members
InstallationNotRequired ni
is disjoint with
InstallationUnknown c, Installed c, NotInstalled c, PartiallyInstalled c
is also defined as
named individual

InstallationStatusc back to ToC or Class ToC

IRI: https://w3id.org/ficr#InstallationStatus

Whether a fire safety system or component is installed, and if so, to what specification.
has super-classes
AssessmentState c
has sub-classes
InstallationNotRequired c, InstallationUnknown c, Installed c, NotInstalled c, PartiallyInstalled c
is in range of
hasInstallationStatus op

InstallationUnknownc back to ToC or Class ToC

IRI: https://w3id.org/ficr#InstallationUnknown

has super-classes
InstallationStatus c
has members
InstallationUnknown ni
is disjoint with
InstallationNotRequired c, Installed c, NotInstalled c, PartiallyInstalled c
is also defined as
named individual

Installedc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Installed

has super-classes
InstallationStatus c
has members
Installed ni
is disjoint with
InstallationNotRequired c, InstallationUnknown c, NotInstalled c, PartiallyInstalled c
is also defined as
named individual

Kitchenc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Kitchen

has super-classes
SpaceUsage c
has members
Kitchen ni
is disjoint with
Auditorium c, Bathroom c, CirculationUsage c, Gallery c, HabitableRoom c, PlaceOfSpecialHazard c, ServiceUsage c, Warehouse c
is also defined as
named individual

LiftShaftc back to ToC or Class ToC

IRI: https://w3id.org/ficr#LiftShaft

A lift shaft is a vertical passageway in a building where an elevator travels between floors.
has super-classes
ShaftSpace c

LiftSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#LiftSystem

Complete machinery and infrastructure for vertical transport.
has super-classes
VerticalTransportSystem c

Lobbyc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Lobby

has super-classes
CirculationUsage c
has members
Lobby ni
is disjoint with
Corridor c, EntranceHall c, Foyer c, Hall c
is also defined as
named individual

MaintenanceRecordEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#MaintenanceRecordEvidence

A document evidence item representing a maintenance record that supports an assessment finding or record.
has super-classes
DocumentEvidence c

MeansOfEscapeRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#MeansOfEscapeRole

has super-classes
EscapeAndEvacuationRole c
has members
MeansOfEscapeRole ni
is also defined as
named individual

MultiStoreyBuildingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#MultiStoreyBuilding

The building is regarded as a multi-storey building if both of the following apply. • There is more than one gallery. • The total aggregate area of all the galleries in one space is more than half the floor area of that space.
has super-classes
Building c
is disjoint with
SingleStoreyBuilding c

NonCompliantResultc back to ToC or Class ToC

IRI: https://w3id.org/ficr#NonCompliantResult

has super-classes
ComplianceResult c
has members
NonCompliantResult ni
is disjoint with
CompliantResult c, UndeterminedResult c
is also defined as
named individual

NotApplicablec back to ToC or Class ToC

IRI: https://w3id.org/ficr#NotApplicable

has super-classes
ApplicabilityState c
has members
NotApplicable ni
is disjoint with
Applicable c, NotAssessed c
is also defined as
named individual

NotAssessedc back to ToC or Class ToC

IRI: https://w3id.org/ficr#NotAssessed

has super-classes
ApplicabilityState c
has members
NotAssessed ni
is disjoint with
Applicable c, NotApplicable c
is also defined as
named individual

NotInstalledc back to ToC or Class ToC

IRI: https://w3id.org/ficr#NotInstalled

has super-classes
InstallationStatus c
has members
NotInstalled ni
is disjoint with
InstallationNotRequired c, InstallationUnknown c, Installed c, PartiallyInstalled c
is also defined as
named individual

ObservedEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ObservedEvidence

Evidence collected from the building or its digital sensors during inspection or monitoring, such as RGB images, depth, LiDAR/point clouds, and sensor readings. This class represents the content used for assessment, not the provenance metadata standard itself.
has super-classes
EvidenceItem c

Officec back to ToC or Class ToC

IRI: https://w3id.org/ficr#Office

has super-classes
UtilizationPurpose c
has members
Office ni
is also defined as
named individual

Openingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Opening

Refers to any intentional void in walls, floors, or ceilings for access, light, air, or services, such as doors, windows, ducts, or stairwells.
has super-classes
FabricElement c
has sub-classes
RooflightOpening c

Operationalc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Operational

has super-classes
ImpairmentState c
has members
Operational ni
is disjoint with
Impaired c, ImpairmentUnknown c
is also defined as
named individual

PartiallyInstalledc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PartiallyInstalled

has super-classes
InstallationStatus c
has members
PartiallyInstalled ni
is disjoint with
InstallationNotRequired c, InstallationUnknown c, Installed c, NotInstalled c
is also defined as
named individual

PassiveFireProtectionRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#PassiveFireProtectionRole

has super-classes
FireProtectionRole c
has members
PassiveFireProtectionRole ni
is also defined as
named individual

PhotographEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#PhotographEvidence

A document evidence item representing a photograph that supports an assessment finding or record.
has super-classes
DocumentEvidence c

PhysicalObjectc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PhysicalObject

A tangible object relevant to fire-related assessment. A physical object may be a building element, equipment item, or building content. Only those physical objects that participate in the building topology are aligned with bot:Element.
has sub-classes
BuildingContent c, Equipment c, FabricElement c, FireProtectionElement c
is in domain of
hasPhysicalObjectFireSafetyRole op, isLocatedIn op
is in range of
aboutElement op, assessesElement op, concernsElement op, hasComponent op

PipingSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PipingSystem

A building system composed of pipes, fittings, valves, and related components for conveying water, gas, or other fluids within or through a building.
has super-classes
BuildingSystem c
has sub-classes
FireSprinklerSystem c

PlaceOfSpecialHazardc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PlaceOfSpecialHazard

has super-classes
SpaceUsage c
has sub-classes
BoilerRoom c, EngineRoom c, FuelStorage c, SwitchGearRoom c, TransformerRoom c
has members
PlaceOfSpecialHazard ni
is disjoint with
Auditorium c, Bathroom c, CirculationUsage c, Gallery c, HabitableRoom c, Kitchen c, ServiceUsage c, Warehouse c
is also defined as
named individual

ProtectedCircuitc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ProtectedCircuit

An electrical circuit that is protected against fire.
is equivalent to
Circuit c and (hasSystemFireSafetyRole op some PassiveFireProtectionRole c)
has super-classes
FireProtectionSystem c

ProtectedCorridorc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ProtectedCorridor

A corridor that is adequately protected from fire in adjoining areas by fire resisting construction.
is equivalent to
Zone c and (hasZoneFireSafetyRole op some PassiveFireProtectionRole c) and (hasSpaceUsage op value Corridor ni)
has super-classes
FireProtectionSpatialProvision c
is disjoint with
ProtectedEntranceHall c, ProtectedLobby c, ProtectedShaft c, ProtectedStairwaySpace c

ProtectedEntranceHallc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ProtectedEntranceHall

A circulation area, consisting of a hall or space in a flat, that is enclosed with fire resisting construction other than an external wall of a building.
is equivalent to
Zone c and (hasZoneFireSafetyRole op some PassiveFireProtectionRole c) and (hasSpaceUsage op value EntranceHall ni)
has super-classes
FireProtectionSpatialProvision c
is disjoint with
ProtectedCorridor c, ProtectedLobby c, ProtectedShaft c, ProtectedStairwaySpace c

ProtectedLobbyc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ProtectedLobby

A corridor or lobby that is adequately protected from fire in adjoining areas by fire resisting construction.
is equivalent to
Zone c and (hasZoneFireSafetyRole op some PassiveFireProtectionRole c) and (hasSpaceUsage op value Lobby ni)
has super-classes
FireProtectionSpatialProvision c
is disjoint with
ProtectedCorridor c, ProtectedEntranceHall c, ProtectedShaft c, ProtectedStairwaySpace c

ProtectedShaftc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ProtectedShaft

A shaft that enables people, air or objects to pass from one compartment to another, and which is enclosed with fire resisting construction.
is equivalent to
Zone c and (containsSystem op some VerticalTransportSystem c) and (hasZoneFireSafetyRole op some PassiveFireProtectionRole c)
has super-classes
FireProtectionSpatialProvision c
is disjoint with
ProtectedCorridor c, ProtectedEntranceHall c, ProtectedLobby c, ProtectedStairwaySpace c

ProtectedStairwayc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ProtectedStairway

A stair that leads to a final exit to a place of safety and that is adequately enclosed with fire resisting construction. Included in the definition is any exit passageway between the foot of the stair and the final exit.
is equivalent to
Stair c and (hasPhysicalObjectFireSafetyRole op some PassiveFireProtectionRole c)
has super-classes
FireProtectionElement c, Stair c

ProtectedStairwaySpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ProtectedStairwaySpace

A stairway space that leads to a final exit to a place of safety and that is adequately enclosed with fire resisting construction. Included in the definition is any exit passageway between the foot of the stair and the final exit.
is equivalent to
Zone c and (contains element op some Stair c) and (hasZoneFireSafetyRole op some PassiveFireProtectionRole c)
has super-classes
FireProtectionSpatialProvision c
is disjoint with
ProtectedCorridor c, ProtectedEntranceHall c, ProtectedLobby c, ProtectedShaft c

PurposeGroupc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup

Classification of a building or compartment by its intended use according to ADB Table 0.1.
has super-classes
RegulatoryClassification c
has sub-classes
PurposeGroup1 c, PurposeGroup2 c, PurposeGroup3 c, PurposeGroup4 c, PurposeGroup5 c, PurposeGroup6 c, PurposeGroup7 c
is in range of
appliesToPurposeGroup op, hasPurposeGroup op

PurposeGroup1c back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup1

A dwelling is a unit where one or more people live (whether or not as a sole or main residence) in either of the following situations. • A single person or people living together as a family. • A maximum of six people living together as a single household, including where care is provided for residents.
has super-classes
PurposeGroup c
has sub-classes
PurposeGroup1a c, PurposeGroup1b c, PurposeGroup1c c

PurposeGroup1ac back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup1a

has super-classes
PurposeGroup1 c
has members
PurposeGroup1a ni
is also defined as
named individual

PurposeGroup1bc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup1b

has super-classes
PurposeGroup1 c
has members
PurposeGroup1b ni
is also defined as
named individual

PurposeGroup1cc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup1c

has super-classes
PurposeGroup1 c
has members
PurposeGroup1c ni
is also defined as
named individual

PurposeGroup2c back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup2

Residential other than Dwellings.
has super-classes
PurposeGroup c
has sub-classes
PurposeGroup2a c, PurposeGroup2b c

PurposeGroup2ac back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup2a

has super-classes
PurposeGroup2 c
has members
PurposeGroup2a ni
is also defined as
named individual

PurposeGroup2bc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup2b

has super-classes
PurposeGroup2 c
has members
PurposeGroup2b ni
is also defined as
named individual

PurposeGroup3c back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup3

has super-classes
PurposeGroup c
has members
PurposeGroup3 ni
is also defined as
named individual

PurposeGroup4c back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup4

has super-classes
PurposeGroup c
has members
PurposeGroup4 ni
is also defined as
named individual

PurposeGroup5c back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup5

has super-classes
PurposeGroup c
has members
PurposeGroup5 ni
is also defined as
named individual

PurposeGroup6c back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup6

has super-classes
PurposeGroup c
has members
PurposeGroup6 ni
is also defined as
named individual

PurposeGroup7c back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup7

Storage and Car Parking
has super-classes
PurposeGroup c
has sub-classes
PurposeGroup7a c, PurposeGroup7b c

PurposeGroup7ac back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup7a

has super-classes
PurposeGroup7 c
has members
PurposeGroup7a ni
is also defined as
named individual

PurposeGroup7bc back to ToC or Class ToC

IRI: https://w3id.org/ficr#PurposeGroup7b

has super-classes
PurposeGroup7 c
has members
PurposeGroup7b ni
is also defined as
named individual

Railingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Railing

A railing refers to a protective barrier or fence, usually made of metal (such as wrought or cast iron, steel, or aluminium), timber, or plastic, designed to provide safety and support.
has super-classes
FabricElement c

RegulatoryClassificationc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RegulatoryClassification

A classification derived from a regulatory source and used to organise compliance requirements or assessment criteria.
has super-classes
Classification c
has sub-classes
PurposeGroup c

RegulatoryInstrumentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RegulatoryInstrument

Laws, regulations, and regulatory documents with statutory binding force.
has super-classes
RegulatorySource c

RegulatoryRequirementc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RegulatoryRequirement

A requirement specification derived from a regulatory, standards, or guidance source. It records the applicable scope, required value or criterion, clause reference, jurisdiction, and source traceability.
has super-classes
RequirementSpecification c
is in domain of
appliesToElementType op, appliesToPurposeGroup op, derivedFromRegulatorySource op, hasClauseReference dp, hasRequiredREI dp
is in range of
checksRequirement op

RegulatorySourcec back to ToC or Class ToC

IRI: https://w3id.org/ficr#RegulatorySource

A referenced regulatory or standards document used as the normative basis for a check or requirement, such as Approved Document B, BDM02, or related standards. It provides the requirement context and should be versioned where possible.
has super-classes
AssessmentBasis c
has sub-classes
GuidanceDocument c, RegulatoryInstrument c, Standard c
is in domain of
hasJurisdiction dp, hasSourceEdition dp, hasSourcePublisher dp
is in range of
derivedFromRegulatorySource op

RelevantBoundaryc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RelevantBoundary

The boundary or notional boundary that one side of the building faces and/or coincides with, and that is parallel or at an angle of a maximum of 80 degrees to that side of the building.
has super-classes
SiteBoundary c

RequirementSpecificationc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RequirementSpecification

A structured specification of a requirement, criterion, or threshold used in assessment. Requirement specifications may be derived from regulations, standards, guidance documents, or project-specific assessment criteria.
has sub-classes
RegulatoryRequirement c

ResidentialCollegec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ResidentialCollege

has super-classes
UtilizationPurpose c
has members
ResidentialCollege ni
is also defined as
named individual

RiskAnalysisc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RiskAnalysis

An assessment that supports risk-informed interpretation by using risk units, fire risk scenarios, compliance findings, boundary condition records, condition states, and evidence status. It does not perform full quantitative fire risk calculation in the FiCR core ontology.
has super-classes
Assessment c
is in domain of
hasScenario op, usesComplianceFinding op

RiskFindingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RiskFinding

An assessment finding produced by risk analysis. It records risk-relevant interpretation for a risk unit, scenario, element, system, or zone, using compliance findings, boundary condition records, and evidence status as inputs.
has super-classes
AssessmentFinding c
is in domain of
derivedFromScenario op
is disjoint with
ComplianceFinding c, InspectionFinding c

RiskUnitc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RiskUnit

A spatial or operational aggregation unit used for fire risk interpretation, evidence-gap review, and inspection prioritisation during O&M. A risk unit may correspond to a dwelling unit, compartment, floor area, tenancy, fire area, or other assessment-defined unit.
is in domain of
coversSpatialZone op, hasSeparationRecord op, isExposedTo op
is in range of
appliesToRiskUnit op, concernsRiskUnit op, hasScenarioRiskUnit op, isExposedTo op

Roofc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Roof

A roof is the top covering of a building that provides protection from the elements like rain, sun, snow, and wind.
has super-classes
FabricElement c
has sub-classes
RoofSlab c

Rooflightc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Rooflight

A dome light, lantern light, ridge light.
has super-classes
Closing c

RooflightOpeningc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RooflightOpening

A skylight, glazed barrel vault or other element to admit daylight through a roof.
has super-classes
Opening c

RoofSlabc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RoofSlab

A horizontal structural slab forming the topmost floor of a building, directly supporting the roof covering and transferring loads to walls or columns.
has super-classes
Roof c, Slab c

RoofSpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#RoofSpace

A roof space is the area inside a building between the ceiling of the top floor and the underside of the roof.
has super-classes
Space c
is disjoint with
AtriumSpace c, BalconySpace c, CavitySpace c, DuctSpace c, RoomSpace c, ShaftSpace c, StairSpace c

RoomSpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#RoomSpace

An enclosed space within a building that is not used solely as a circulation space. The term includes not only conventional rooms, but also cupboards that are not fittings and large spaces such as warehouses and auditoria. The term does not include cavities such as ducts, ceiling cavities and roof spaces.
has super-classes
Space c
is disjoint with
AtriumSpace c, BalconySpace c, CavitySpace c, DuctSpace c, RoofSpace c, ShaftSpace c, StairSpace c

RoutineTriggerEventc back to ToC or Class ToC

IRI: https://w3id.org/ficr#RoutineTriggerEvent

A trigger event generated from routine schedules or planned inspection cycles derived from FiCR maintenance and regulatory schedules, such as monthly fire exit checks.
has super-classes
Event c

Schoolc back to ToC or Class ToC

IRI: https://w3id.org/ficr#School

has super-classes
UtilizationPurpose c
has members
School ni
is also defined as
named individual

SelfClosingDevicec back to ToC or Class ToC

IRI: https://w3id.org/ficr#SelfClosingDevice

A device that closes a door, when open at any angle, against a door frame. NOTE: If the door is in a cavity barrier, rising butt hinges (which are different from the self-closing device mentioned above) are acceptable.
has super-classes
Closing c

Sensorc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Sensor

A sensor in a building is a device that detects environmental changes and sends data to a control system to manage building functions like lighting, HVAC, and safety.
has super-classes
Equipment c

SensorEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#SensorEvidence

An evidence item generated by a sensor or monitoring device to support an assessment finding or record.
has super-classes
EvidenceItem c

ServiceShaftc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ServiceShaft

A service shaft is a vertical passage in a building that houses pipes, cables, and ducts for essential building systems like water, electricity, and ventilation.
has super-classes
ShaftSpace c

ServiceUsagec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ServiceUsage

has super-classes
SpaceUsage c
has members
ServiceUsage ni
is disjoint with
Auditorium c, Bathroom c, CirculationUsage c, Gallery c, HabitableRoom c, Kitchen c, PlaceOfSpecialHazard c, Warehouse c
is also defined as
named individual

ShaftSpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#ShaftSpace

A smaller, enclosed vertical space extending through multiple floors used for specific building services, such as elevator hoistways, enclosed stairwells, or ducts for plumbing, electrical, or air-conditioning equipment.
is equivalent to
Space c and (containsSystem op some VerticalTransportSystem c)
has super-classes
Space c
has sub-classes
LiftShaft c, ServiceShaft c
is disjoint with
AtriumSpace c, BalconySpace c, CavitySpace c, DuctSpace c, RoofSpace c, RoomSpace c, StairSpace c

ShelteredHousingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#ShelteredHousing

has super-classes
UtilizationPurpose c
has members
ShelteredHousing ni
is also defined as
named individual

Shopc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Shop

has super-classes
UtilizationPurpose c
has members
Shop ni
is also defined as
named individual

SingleStoreyBuildingc back to ToC or Class ToC

IRI: https://w3id.org/ficr#SingleStoreyBuilding

A building that consists of a ground storey only. Basements are not counted as storeys in a building (see Appendix D). A separated part that consists of a ground storey only, with a roof to which access is only provided for repair or maintenance, may be treated as a single storey building.
has super-classes
Building c
is disjoint with
MultiStoreyBuilding c

SiteBoundaryc back to ToC or Class ToC

IRI: https://w3id.org/ficr#SiteBoundary

A spatial boundary representing the extent of the site or land associated with a building. This class is not used to represent fire compartment boundaries or boundary condition records.
has super-classes
Zone c
has sub-classes
RelevantBoundary c

Slabc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Slab

A slab is the thick, structural concrete element (like reinforced concrete) forming a building's horizontal plane
has super-classes
StructuralElement c
has sub-classes
FloorSlab c, RoofSlab c

SolarShadingDevicec back to ToC or Class ToC

IRI: https://w3id.org/ficr#SolarShadingDevice

A device attached to the external surface of an external wall for reducing heat gain within a building by shading or deflecting sunlight.
has super-classes
SpecifiedAttachment c

SpaceUsagec back to ToC or Class ToC

IRI: https://w3id.org/ficr#SpaceUsage

Describe the uses of the space.
has super-classes
UsageType c
has sub-classes
Auditorium c, Bathroom c, CirculationUsage c, Gallery c, HabitableRoom c, Kitchen c, PlaceOfSpecialHazard c, ServiceUsage c, Warehouse c
is in range of
hasSpaceUsage op

SpecifiedAttachmentc back to ToC or Class ToC

IRI: https://w3id.org/ficr#SpecifiedAttachment

Includes any of the following. • A balcony attached to an external wall. • A device for reducing heat gain within a building by deflecting sunlight which is attached to an external wall.
has super-classes
FabricElement c
has sub-classes
SolarShadingDevice c

Stairc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Stair

a stairway (or staircase) is a series of steps connecting different levels in a building, serving as a pedestrian route.
has super-classes
FabricElement c
has sub-classes
ProtectedStairway c

StairFlightc back to ToC or Class ToC

IRI: https://w3id.org/ficr#StairFlight

A stair flight (or simply "flight") refers to an uninterrupted, continuous sequence of stairs (steps/risers) that connect two levels, floors, or intermediate landings.
has super-classes
FabricElement c

StairSpacec back to ToC or Class ToC

IRI: https://w3id.org/ficr#StairSpace

A stairway space, also called a stairwell, is the vertical compartment in a building that contains a flight of stairs and the associated landings, hallways, or other areas needed to move between floors.
is equivalent to
Space c and (contains element op some Stair c)
has super-classes
Space c
is disjoint with
AtriumSpace c, BalconySpace c, CavitySpace c, DuctSpace c, RoofSpace c, RoomSpace c, ShaftSpace c

Standardc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Standard

Technical standards, codes, or guides issued by standards organizations are typically technical specifications; whether they are mandatory depends on whether they are cited in regulations, contracts, or by an authority.
has super-classes
RegulatorySource c
has members
B S E N 12845 ni

Storagec back to ToC or Class ToC

IRI: https://w3id.org/ficr#Storage

has super-classes
UtilizationPurpose c
has members
Storage ni
is also defined as
named individual

StoreyExitRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#StoreyExitRole

has super-classes
EscapeAndEvacuationRole c
has members
StoreyExitRole ni
is also defined as
named individual

StructuralElementc back to ToC or Class ToC

IRI: https://w3id.org/ficr#StructuralElement

A structural element is a component of a building that is essential for its stability and for transferring loads to the ground, such as foundations, beams, columns, and load-bearing walls.
has super-classes
FabricElement c
has sub-classes
Beam c, Column c, Slab c, Wall c, WallFoundation c

StructuralStabilityPerformanceAspectc back to ToC or Class ToC

IRI: https://w3id.org/ficr#StructuralStabilityPerformanceAspect

has super-classes
BoundaryPerformanceAspect c
has members
StructuralStabilityPerformanceAspect ni
is also defined as
named individual

SwitchGearRoomc back to ToC or Class ToC

IRI: https://w3id.org/ficr#SwitchGearRoom

has super-classes
PlaceOfSpecialHazard c
has members
SwitchGearRoom ni
is disjoint with
BoilerRoom c, EngineRoom c, FuelStorage c, TransformerRoom c
is also defined as
named individual

Taskc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Task

A workflow task in FiCR. Tasks organise how evidence is collected, how compliance checking or risk analysis is initiated, and how assessments are produced during fire-related O&M activity.
has sub-classes
ComplianceCheckingTask c, EquipmentInspectionTask c, FireRiskAssessmentTask c
is in domain of
plannedEndTime dp, plannedStartTime dp, producesAssessment op, producesEvidence op, triggeredBy op, usesEvidence op
is in range of
triggersTask op

TestEvidencec back to ToC or Class ToC

IRI: https://w3id.org/ficr#TestEvidence

An evidence item generated by a test or measurement activity to support an assessment finding or record.
has super-classes
EvidenceItem c

TransformerRoomc back to ToC or Class ToC

IRI: https://w3id.org/ficr#TransformerRoom

has super-classes
PlaceOfSpecialHazard c
has members
TransformerRoom ni
is disjoint with
BoilerRoom c, EngineRoom c, FuelStorage c, SwitchGearRoom c
is also defined as
named individual

UndeterminedResultc back to ToC or Class ToC

IRI: https://w3id.org/ficr#UndeterminedResult

has super-classes
ComplianceResult c
has members
UndeterminedResult ni
is disjoint with
CompliantResult c, NonCompliantResult c
is also defined as
named individual

Unknownc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Unknown

has super-classes
ConditionState c
has members
Unknown ni
is disjoint with
Compromised c, Effective c
is also defined as
named individual

UnprotectedAreaRolec back to ToC or Class ToC

IRI: https://w3id.org/ficr#UnprotectedAreaRole

has super-classes
FireProtectionRole c
has members
UnprotectedAreaRole ni
is also defined as
named individual

UsageTypec back to ToC or Class ToC

IRI: https://w3id.org/ficr#UsageType

A controlled classification value used to assign use, purpose, or fire-safety role to buildings, spaces, physical objects, zones, or systems. UsageType values are used as controlled vocabulary terms and may be represented through OWL punning where required for value-based class definitions.
has sub-classes
FireSafetyRole c, SpaceUsage c, UtilizationPurpose c
is in range of
hasUsageType op

UtilizationPurposec back to ToC or Class ToC

IRI: https://w3id.org/ficr#UtilizationPurpose

Assigns the planning or occupancy use of a building, such as dwellinghouse, office, hotel, school, shop, or factory. This is distinct from regulatory purpose group classification.
has super-classes
UsageType c
has sub-classes
Accommodation c, AssemblyPlace c, BoardingHouse c, CarParking c, CommercialPlace c, DetentionHouse c, Dwellinghouse c, EntertainmentPlace c, Factory c, Flat c, HallOfResidence c, Hospital c, Hostel c, Hotel c, Office c, ResidentialCollege c, School c, ShelteredHousing c, Shop c, Storage c
is in range of
hasUtilizationPurpose op

VerticalTransportSystemc back to ToC or Class ToC

IRI: https://w3id.org/ficr#VerticalTransportSystem

A Vertical Transport System (VT) in buildings refers to the equipment and planning used to move people and goods vertically between different floors.
has super-classes
BuildingSystem c
has sub-classes
LiftSystem c

Wallc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Wall

A wall in buildings is a vertical structure that defines and separates spaces, provides shelter and security, and can be either load-bearing or non-load-bearing.
has super-classes
StructuralElement c
has sub-classes
CompartmentWall c, ExternalWall c

WallFoundationc back to ToC or Class ToC

IRI: https://w3id.org/ficr#WallFoundation

Sub-structure component, typically concrete, brick, or masonry, that transfers loads from the building's walls down to the ground or a concrete footing
has super-classes
StructuralElement c

Warehousec back to ToC or Class ToC

IRI: https://w3id.org/ficr#Warehouse

has super-classes
SpaceUsage c
has members
Warehouse ni
is disjoint with
Auditorium c, Bathroom c, CirculationUsage c, Gallery c, HabitableRoom c, Kitchen c, PlaceOfSpecialHazard c, ServiceUsage c
is also defined as
named individual

Windowc back to ToC or Class ToC

IRI: https://w3id.org/ficr#Window

A window is an opening in a building wall for light and air, featuring casements or sashes with glass panes, enhancing natural lighting, ventilation, and aesthetics.
has super-classes
Closing c
has sub-classes
ExternalWallWindow c

Object Properties

aboutElementop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#aboutElement

Links a boundary condition record to the physical object whose fire-related boundary or performance condition it concerns.
has domain
BoundaryConditionRecord c
has range
PhysicalObject c

appliesToElementTypeop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#appliesToElementType

Specifies the class of physical element this requirement applies to, e.g. ficr:Wall or ficr:Floor.
has domain
RegulatoryRequirement c

appliesToPurposeGroupop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#appliesToPurposeGroup

Specifies the building purpose group for which this requirement is applicable.
has domain
RegulatoryRequirement c
has range
PurposeGroup c

appliesToRiskUnitop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#appliesToRiskUnit

Links a boundary condition record to the risk unit whose fire risk interpretation it informs.
has domain
BoundaryConditionRecord c
has range
RiskUnit c

assessesElementop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#assessesElement

Links an assessment to the physical element(s) it evaluates. For compliance assessments, this is the wall, door, or floor being checked. For risk assessments, this covers elements involved in fire spread modelling.
has domain
Assessment c
has range
PhysicalObject c

assessesZoneop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#assessesZone

Links an assessment to the zone(s) or space(s) it covers. For risk assessments, this is the space whose fire scenario is being evaluated. For compliance assessments, this is the space containing the assessed elements.
has domain
Assessment c
has range
Zone c

checksRequirementop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#checksRequirement

Links a compliance finding to the regulatory requirement being checked.
has domain
ComplianceFinding c
has range
RegulatoryRequirement c

concernsElementop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#concernsElement

Links an assessment finding to the physical object it concerns.
has domain
AssessmentFinding c
has range
PhysicalObject c

concernsRiskUnitop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#concernsRiskUnit

Links an assessment finding to the risk unit it concerns.
has domain
AssessmentFinding c
has range
RiskUnit c

concernsSystemop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#concernsSystem

Links an assessment finding to the building system it concerns.
has domain
AssessmentFinding c
has range
BuildingSystem c

concernsZoneop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#concernsZone

Links an assessment finding to the spatial zone or space it concerns.
has domain
AssessmentFinding c
has range
Zone c

containsSystemop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#containsSystem

Relates a spatial zone to a building system located in, passing through, or spatially associated with that zone. This property is used where a system-level entity should not be treated as a BOT element.
has domain
Zone c
has range
BuildingSystem c
is inverse of
isSystemContainedIn op

coversSpatialZoneop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#coversSpatialZone

Links a risk unit to the spatial zone whose fire exposure it aggregates.
has domain
RiskUnit c
has range
Zone c

dependsOnBoundaryConditionop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#dependsOnBoundaryCondition

Links a fire risk scenario to boundary condition records or assumptions that influence the scenario interpretation.
has domain
FireRiskScenario c
has range
BoundaryConditionRecord c

derivedFromRegulatorySourceop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#derivedFromRegulatorySource

Links a regulatory requirement individual to the regulatory, standard, or guidance source from which it was derived.
has domain
RegulatoryRequirement c
has range
RegulatorySource c

derivedFromScenarioop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#derivedFromScenario

Links a risk finding to the fire risk scenario from which it was derived, enabling finding-level traceability when one risk analysis evaluates multiple scenarios.
has domain
RiskFinding c
has range
FireRiskScenario c

hasApplicabilityStateop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasApplicabilityState

Records whether an assessment finding or checklist item is applicable, not applicable, or not assessed in the current assessment scope.
has domain
AssessmentFinding c
has range
ApplicabilityState c

hasAssessmentBasisop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasAssessmentBasis

Links an assessment activity or assessment result to the evidence bundle that supports it.
has domain
Assessment c
has range
AssessmentBasis c

hasBoundaryPerformanceAspectop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasBoundaryPerformanceAspect

Identifies the boundary-related performance aspect assessed by a boundary condition record.

hasClassificationop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasClassification

General property relating an entity to its classification.
has sub-properties
hasPurposeGroup op
is inverse of
isClassificationOf op

hasComplianceResultop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasComplianceResult

Links a compliance finding to its compliance result.
has domain
ComplianceFinding c
has range
ComplianceResult c

hasComponentop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasComponent

Expressing the compositional relationship of components
has domain
BuildingSystem c
has range
PhysicalObject c
is inverse of
isComponentOf op

hasConditionStateop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasConditionState

Links a boundary condition record to its assessed condition state, such as effective, compromised, or unknown.
has domain
BoundaryConditionRecord c
has range
ConditionState c

hasConnectionWithop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasConnectionWith

indicates that the two individuals have a passageway.

hasEvidenceStatusop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasEvidenceStatus

Links an assessment finding, boundary condition record, or other assessment-related record to a controlled evidence status. The domain is intentionally left open to avoid forcing all evidence-qualified records into the AssessmentFinding hierarchy.
has range
EvidenceStatus c

hasFireRiskUnitRoleop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasFireRiskUnitRole

Assigns a fire risk unit role to an entity.
has super-properties
hasUsageType op
is inverse of
isFireRiskUnitRoleOf op

hasFireSafetyRoleop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasFireSafetyRole

General property linking an entity to a fire safety role. More specific subproperties are used for physical objects, zones, and systems.
has super-properties
hasUsageType op
has sub-properties
hasPhysicalObjectFireSafetyRole op, hasSystemFireSafetyRole op, hasZoneFireSafetyRole op
has range
FireSafetyRole c
is inverse of
isFireSafetyRoleOf op

hasImpairmentStateop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasImpairmentState

Links an asset, system, provision, or relevant physical object to its operational impairment state. The domain is intentionally left open because impairment may apply to fire-protection provisions, general equipment, building systems, or other inspected assets.
has range
ImpairmentState c

hasInstallationStatusop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasInstallationStatus

Links an asset, system, provision, or relevant physical object to its installation status. The domain is intentionally left open because installation status may apply to fire-protection provisions, general equipment, and building systems.
has range
InstallationStatus c

hasOriginSpaceop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasOriginSpace

Links a fire risk scenario to the zone where the fire is modelled to originate.
has domain
FireRiskScenario c
has range
Zone c

hasPhysicalObjectFireSafetyRoleop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasPhysicalObjectFireSafetyRole

Assigns a fire safety role to a physical object, such as a wall, doorset, stair, damper, equipment item, or other object relevant to fire assessment.
has super-properties
hasFireSafetyRole op
has domain
PhysicalObject c
has range
FireSafetyRole c
is inverse of
isPhysicalObjectFireSafetyRoleOf op

hasPurposeGroupop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasPurposeGroup

Relates a building to its functional purpose group classification according to ADB Table 0.1
has super-properties
hasClassification op
has domain
Building c
has range
PurposeGroup c
is inverse of
isPurposeGroupOf op

hasScenarioop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasScenario

Links a risk analysis to the fire risk scenario or scenarios it evaluates. Each scenario represents a hypothetical fire origin and relevant spread or exposure context used for risk-informed interpretation.
has domain
RiskAnalysis c
has range
FireRiskScenario c

hasScenarioRiskUnitop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasScenarioRiskUnit

Links a fire risk scenario to the risk unit whose fire risk is being interpreted.
has domain
FireRiskScenario c
has range
RiskUnit c

hasSeparationRecordop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasSeparationRecord

Links a risk unit to a separation distance record describing its exposure to an adjacent risk unit.
has domain
RiskUnit c

hasSpaceUsageop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasSpaceUsage

Assigns an everyday or operational space-use classification to a spatial zone or space, such as kitchen, corridor, lobby, bathroom, habitable room, or place of special hazard.
has super-properties
hasUsageType op
has domain
Zone c
has range
SpaceUsage c
is inverse of
isSpaceUsageOf op

hasSystemFireSafetyRoleop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasSystemFireSafetyRole

Assigns a fire safety role to a building system, such as active protection, protected supply, evacuation support, or firefighting support.
has super-properties
hasFireSafetyRole op
has domain
BuildingSystem c
has range
FireSafetyRole c
is inverse of
isSystemFireSafetyRoleOf op

hasUsageTypeop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasUsageType

Top-level property linking an entity to a usage type classification. Sub-properties specialise domain and range.
has sub-properties
hasFireRiskUnitRole op, hasFireSafetyRole op, hasSpaceUsage op, hasUtilizationPurpose op
has range
UsageType c
is inverse of
isUsageTypeOf op

hasUtilizationPurposeop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasUtilizationPurpose

Assigns a building planning utilization purpose (e.g. Hotel, Office) to a zone or building.
has super-properties
hasUsageType op
has domain
Building c
has range
UtilizationPurpose c
is inverse of
isUtilizationPurposeOf op

hasZoneFireSafetyRoleop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#hasZoneFireSafetyRole

Assigns a fire safety role to a spatial zone, enabling protected-space and route-related classifications.
has super-properties
hasFireSafetyRole op
has domain
Zone c
has range
FireSafetyRole c
is inverse of
isZoneFireSafetyRoleOf op

isClassificationOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isClassificationOf

Inverse of hasClassification.
has sub-properties
isPurposeGroupOf op
is inverse of
hasClassification op

isComponentOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isComponentOf

Links an individual equipment item to the building system it belongs to. Inverse direction of hasComponent at the instance level.
is inverse of
hasComponent op

isExposedToop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isExposedTo

Indicates potential fire spread exposure between risk units.
has domain
RiskUnit c
has range
RiskUnit c

isFireRiskUnitRoleOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isFireRiskUnitRoleOf

Inverse of hasFireRiskUnitRole.
has super-properties
isUsageTypeOf op
is inverse of
hasFireRiskUnitRole op

isFireSafetyRoleOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isFireSafetyRoleOf

Inverse of hasFireSafetyRole.
has super-properties
isUsageTypeOf op
has range
FireSafetyRole c
is inverse of
hasFireSafetyRole op

isLocatedInop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isLocatedIn

describe the location and/or surroundings of a place.
has domain
PhysicalObject c
has range
Zone c

isPhysicalObjectFireSafetyRoleOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isPhysicalObjectFireSafetyRoleOf

Inverse of hasPhysicalObjectFireSafetyRole
has super-properties
isUsageTypeOf op
is inverse of
hasPhysicalObjectFireSafetyRole op

isPurposeGroupOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isPurposeGroupOf

Inverse of hasPurposeGroup.
has super-properties
isClassificationOf op
is inverse of
hasPurposeGroup op

isSpaceUsageOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isSpaceUsageOf

Inverse of hasSpaceUsage.
has super-properties
isUsageTypeOf op
is inverse of
hasSpaceUsage op

isStoreyAboveop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isStoreyAbove

Indicates that the subject storey is directly above the object storey.
has domain
Storey c
has range
Storey c

isStoreyBelowop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isStoreyBelow

Indicates that the subject storey is directly below the object storey.
has domain
Storey c
has range
Storey c

isSystemContainedInop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isSystemContainedIn

inverseOf containsSystem
has domain
BuildingSystem c
has range
Zone c
is inverse of
containsSystem op

isSystemFireSafetyRoleOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isSystemFireSafetyRoleOf

Inverse of hasFireSafetyRole, linking a fire safety role to the system or element that bears it.
has super-properties
isUsageTypeOf op
is inverse of
hasSystemFireSafetyRole op

isUsageTypeOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isUsageTypeOf

Inverse of hasUsageType.

isUtilizationPurposeOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isUtilizationPurposeOf

Inverse of hasUtilizationPurpose.
has super-properties
isUsageTypeOf op
is inverse of
hasUtilizationPurpose op

isZoneFireSafetyRoleOfop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#isZoneFireSafetyRoleOf

Inverse of hasZoneFireSafetyRole.
has super-properties
isUsageTypeOf op
is inverse of
hasZoneFireSafetyRole op

producesAssessmentop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#producesAssessment

Links a task to the assessment record produced by executing that task.
has domain
Task c
has range
Assessment c

producesEvidenceop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#producesEvidence

Links a task to evidence items it generates.
has domain
Task c
has range
EvidenceItem c

producesFindingop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#producesFinding

Links an assessment to the findings it produces.
has domain
Assessment c
has range
AssessmentFinding c

reliesOnBoundaryConditionop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#reliesOnBoundaryCondition

Links an assessment to a boundary condition record that it relies on or interprets. This allows compliance checking and risk analysis to expose whether their conclusions depend on effective, compromised, unknown, or weakly evidenced boundary conditions.
has domain
Assessment c
has range
BoundaryConditionRecord c

supportedByEvidenceop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#supportedByEvidence

Links an assessment finding, boundary condition record, or other assessment-related record to evidence items that support, justify, or document it. The domain is intentionally left open because evidence support is used both for produced findings and for assessment dependencies such as boundary condition records.
has range
EvidenceItem c

triggeredByop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#triggeredBy

A task is created because an event (e.g., risk detected) occurred.
has domain
Task c
has range
Event c
is inverse of
triggersTask op

triggersTaskop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#triggersTask

Links a trigger event to the task(s) created because of it.
has domain
Event c
has range
Task c
is inverse of
triggeredBy op

usesComplianceFindingop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#usesComplianceFinding

Links a risk analysis to compliance findings used as inputs for risk interpretation.
has domain
RiskAnalysis c
has range
ComplianceFinding c

usesEvidenceop back to ToC or Object Property ToC

IRI: https://w3id.org/ficr#usesEvidence

Links a task to evidence items it consumes as inputs.
has domain
Task c
has range
EvidenceItem c

Data Properties

documentTitledp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#documentTitle

A human-readable title used to display the document in user interfaces.
has domain
AssessmentBasis c
has range
string

documentURIdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#documentURI

A resolvable URI or file path pointing to the document location for human access.
has domain
AssessmentBasis c
has range
any U R I

hasActualREIdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasActualREI

The actual measured fire resistance period (R=load-bearing, E=integrity, I=insulation) in minutes.
has super-properties
top Data Property dp
has range
integer

hasActualSeparationMdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasActualSeparationM

Measured physical separation distance in metres between two risk units.
has range
decimal

hasAreadp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasArea

The floor area of a space in square metres.
has range
decimal

hasBuildingHeightdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasBuildingHeight

Height of a building is measured as shown in Appendix D, Diagram D4.
has domain
Building c
has range
decimal

hasClauseReferencedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasClauseReference

Records the clause, table, paragraph, section, or provision reference from which a regulatory requirement was derived.
has domain
RegulatoryRequirement c
has range
string

hasCombinedGrossFloorAreadp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasCombinedGrossFloorArea

Total gross floor area of all storeys in a building, in square metres.
has domain
Building c
has range
decimal

hasCoverageTypedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasCoverageType

The spatial coverage mode of the detector, e.g. PointDetector, BeamDetector, AspiratingDetector.
has domain
Alarm c

hasDetectionTypedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasDetectionType

The detection principle of the alarm device, e.g. OpticalSmoke, Ionisation, Heat, MultiSensor, CarbonMonoxide.
has domain
Alarm c

hasDirectDistancedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasDirectDistance

The shortest distance from any point within the floor area to the nearest storey exit, measured within the external enclosures of the building, and ignoring walls, partitions and fittings other than the enclosing walls and partitions to protected stairways.
has range
decimal

hasElevationdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasElevation

The vertical height of a storey floor level above a reference datum, in metres.
has range
decimal

hasExtinguisherAgentdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasExtinguisherAgent

The extinguishing agent type, e.g. DryPowder, CO2, WaterMist, WetChemical, Foam.
has domain
FireExtinguisher c

hasFindingStatementdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasFindingStatement

A human-readable statement of what the finding records. Used for expected-vs-actual validation tables and reporting.
has domain
AssessmentFinding c
has range
string

hasFireClassRatingdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasFireClassRating

The fire class rating per BS EN 2, e.g. A, B, AB, ABC, AF.
has domain
FireExtinguisher c

hasFixedAssetValuedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasFixedAssetValue

This refers to the total asset value of the space.
has range
decimal

hasIDdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasID

A unique identifier string for the entity.
has range
string

hasJurisdictiondp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasJurisdiction

Specifies the jurisdiction in which a regulatory source, requirement, or assessment context applies.
has domain
RegulatorySource c
has range
string

hasLengthdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasLength

The length dimension of a building element, in metres.
has range
decimal

hasNumberOfStoreysdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasNumberOfStoreys

Number of storeys excluding basements
has domain
Building c
has range
integer

hasRequiredREIdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasRequiredREI

The minimum REI value mandated by regulation for a given element type and purpose group, in minutes.
has super-properties
top Data Property dp
has domain
RegulatoryRequirement c
has range
integer

hasRequiredSeparationMdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasRequiredSeparationM

Minimum separation distance in metres required to prevent fire spread, computed per NFPA 80A. Stored here as an externally-supplied value; FiCR does not compute this internally.
has range
decimal

hasScenarioDescriptiondp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasScenarioDescription

Provides a narrative description of the fire risk scenario, including where the fire is assumed to originate, how it may spread, and why it is expected to stop or be limited.
has domain
FireRiskScenario c
has range
string

hasServiceExpiryDatedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasServiceExpiryDate

The date by which the equipment must be serviced or replaced to remain compliant.
has domain
Equipment c

hasSourceEditiondp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasSourceEdition

Records the edition, year, version, or publication date of a regulatory, standards, or guidance source.
has domain
RegulatorySource c
has range
string

hasSourcePublisherdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasSourcePublisher

Records the issuing body or publisher of a regulatory, standards, or guidance source.
has domain
RegulatorySource c
has range
string

hasStoreyHeightdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasStoreyHeight

The floor-to-floor height of a storey, in metres.
has range
decimal

hasThicknessdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasThickness

The thickness dimension of a building element, in metres.
has range
decimal

hasTopStoreyFloorHeightdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasTopStoreyFloorHeight

Height of the floor of the top storey above ground level is measured as shown in Appendix D, Diagram D6.
has domain
Building c
has range
decimal

hasTopStoreyHeightdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasTopStoreyHeight

The floor-to-ceiling height of the topmost storey, in metres.
has domain
Building c
has range
decimal

hasTravelDistancedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasTravelDistance

(unless otherwise specified, e.g. as in the case of flats) The distance that a person would travel from any point within the floor area to the nearest storey exit, determined by the layout of walls, partitions and fittings.
has range
decimal

hasVolumedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasVolume

The volume of a space, in cubic metres.
has range
decimal

hasWidthdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#hasWidth

The width dimension of a building element, in metres.
has range
decimal

isAboveGrounddp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#isAboveGround

Determine whether the storey is a basement or above ground.
has domain
Storey c
has range
boolean

isDamageddp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#isDamaged

Boolean indicating whether the element shows visible damage affecting its fire performance.
has range
boolean

isEncloseddp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#isEnclosed

Boolean indicating whether the element or space is fully enclosed by construction.
has range
boolean

isExternaldp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#isExternal

Boolean indicating whether the element forms part of the external building envelope.
has range
boolean

isLoadBearingdp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#isLoadBearing

Boolean indicating whether the element carries structural loads.
has range
boolean

isObscureddp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#isObscured

Refers to the state of being obscured.
has range
boolean

plannedEndTimedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#plannedEndTime

The scheduled end date and time of a task.
has domain
Task c
has range
date Time

plannedStartTimedp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#plannedStartTime

The scheduled start date and time of a task.
has domain
Task c
has range
date Time

requiresInspectiondp back to ToC or Data Property ToC

IRI: https://w3id.org/ficr#requiresInspection

Must be subject to inspection assignments (e.g., fire safety inspections).
has range
boolean

Annotation Properties

according toap back to ToC or Annotation Property ToC

IRI: https://w3id.org/ficr#according_to

alt Labelap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#altLabel

contributorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/contributor

creatorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/creator

descriptionap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/description

domain Includesap back to ToC or Annotation Property ToC

IRI: https://schema.org/domainIncludes

fnap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2006/vcard/ns#fn

issuedap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/issued

licenseap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/license

modifiedap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/modified

nameap back to ToC or Annotation Property ToC

IRI: https://schema.org/name

preferred Namespace Prefixap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespacePrefix

preferred Namespace Uriap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespaceUri

range Includesap back to ToC or Annotation Property ToC

IRI: https://schema.org/rangeIncludes

scope Noteap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#scopeNote

term statusap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2003/06/sw-vocab-status/ns#term_status

titleap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/title

Named Individuals

A D Bni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ADB

Approved Document B Volume 1&2 Building regulation in England covering fire safety matters within and around buildings.
belongs to
GuidanceDocument c

AccessRoomRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#AccessRoomRole

belongs to
AccessRoomRole c
is also defined as
class

Accommodationni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Accommodation

belongs to
Accommodation c
is also defined as
class

ActiveFireProtectionRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ActiveFireProtectionRole

belongs to
ActiveFireProtectionRole c
is also defined as
class

AlternativeEscapeRouteRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#AlternativeEscapeRouteRole

belongs to
AlternativeEscapeRouteRole c
is also defined as
class

AlternativeExitRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#AlternativeExitRole

belongs to
AlternativeExitRole c
is also defined as
class

Applicableni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Applicable

belongs to
Applicable c
is disjoint with
NotApplicable ni, NotAssessed ni
is also defined as
class

AssemblyPlaceni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#AssemblyPlace

belongs to
AssemblyPlace c
is also defined as
class

Auditoriumni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Auditorium

belongs to
Auditorium c
is disjoint with
Bathroom ni, CirculationUsage ni, Gallery ni, HabitableRoom ni, Kitchen ni, PlaceOfSpecialHazard ni, ServiceUsage ni, Warehouse ni
is also defined as
class

B D M02ni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#BDM02

Fire Protection of Buildings RISCAuthority BDM02 - Fire Protection of Buildings - 2022 v2 A4
belongs to
GuidanceDocument c

B S E N 12845ni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#BS_EN_12845

Fixed firefighting systems. Automatic sprinkler systems. Design, installation and maintenance.
belongs to
Standard c

Bathroomni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Bathroom

belongs to
Bathroom c
is disjoint with
Auditorium ni, CirculationUsage ni, Gallery ni, HabitableRoom ni, Kitchen ni, PlaceOfSpecialHazard ni, ServiceUsage ni, Warehouse ni
is also defined as
class

BoardingHouseni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#BoardingHouse

belongs to
BoardingHouse c
is also defined as
class

BoilerRoomni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#BoilerRoom

belongs to
BoilerRoom c
is disjoint with
EngineRoom ni, FuelStorage ni, SwitchGearRoom ni, TransformerRoom ni
is also defined as
class

CarParkingni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#CarParking

belongs to
CarParking c
is also defined as
class

CavityBarrierPerformanceAspectni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#CavityBarrierPerformanceAspect

belongs to
CavityBarrierPerformanceAspect c
is also defined as
class

CirculationSpaceRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#CirculationSpaceRole

belongs to
CirculationSpaceRole c
is also defined as
class

CirculationUsageni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#CirculationUsage

belongs to
CirculationUsage c
is disjoint with
Auditorium ni, Bathroom ni, Gallery ni, HabitableRoom ni, Kitchen ni, PlaceOfSpecialHazard ni, ServiceUsage ni, Warehouse ni
is also defined as
class

CommercialPlaceni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#CommercialPlace

belongs to
CommercialPlace c
is also defined as
class

CompartmentationPerformanceAspectni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#CompartmentationPerformanceAspect

belongs to
CompartmentationPerformanceAspect c
is also defined as
class

CompliantResultni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#CompliantResult

belongs to
CompliantResult c
is disjoint with
NonCompliantResult ni, UndeterminedResult ni
is also defined as
class

Compromisedni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Compromised

belongs to
Compromised c
is disjoint with
Effective ni, Unknown ni
is also defined as
class

Corridorni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Corridor

belongs to
Corridor c
is disjoint with
EntranceHall ni, Foyer ni, Hall ni, Lobby ni
is also defined as
class

DeadEndRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#DeadEndRole

belongs to
DeadEndRole c
is also defined as
class

DetentionHouseni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#DetentionHouse

belongs to
DetentionHouse c
is also defined as
class

Dwellinghouseni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Dwellinghouse

belongs to
Dwellinghouse c
is also defined as
class

Effectiveni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Effective

belongs to
Effective c
is disjoint with
Compromised ni, Unknown ni
is also defined as
class

EngineRoomni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EngineRoom

belongs to
EngineRoom c
is disjoint with
BoilerRoom ni, FuelStorage ni, SwitchGearRoom ni, TransformerRoom ni
is also defined as
class

EntertainmentPlaceni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EntertainmentPlace

belongs to
EntertainmentPlace c
is also defined as
class

EntranceHallni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EntranceHall

belongs to
EntranceHall c
is disjoint with
Corridor ni, Foyer ni, Hall ni, Lobby ni
is also defined as
class

EvacuationRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EvacuationRole

belongs to
EvacuationRole c
is also defined as
class

EvidenceAvailableni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EvidenceAvailable

belongs to
EvidenceAvailable c
is disjoint with
EvidenceInsufficient ni, EvidenceMissing ni, EvidenceNotRequired ni
is also defined as
class

EvidenceInsufficientni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EvidenceInsufficient

belongs to
EvidenceInsufficient c
is disjoint with
EvidenceAvailable ni, EvidenceMissing ni, EvidenceNotRequired ni
is also defined as
class

EvidenceMissingni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EvidenceMissing

belongs to
EvidenceMissing c
is disjoint with
EvidenceAvailable ni, EvidenceInsufficient ni, EvidenceNotRequired ni
is also defined as
class

EvidenceNotRequiredni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#EvidenceNotRequired

belongs to
EvidenceNotRequired c
is disjoint with
EvidenceAvailable ni, EvidenceInsufficient ni, EvidenceMissing ni
is also defined as
class

ExitPassagewayRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ExitPassagewayRole

belongs to
ExitPassagewayRole c
is also defined as
class

ExternalFireSpreadPerformanceAspectni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ExternalFireSpreadPerformanceAspect

belongs to
ExternalFireSpreadPerformanceAspect c
is also defined as
class

Factoryni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Factory

belongs to
Factory c
is also defined as
class

FinalExitRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#FinalExitRole

belongs to
FinalExitRole c
is also defined as
class

FirefightingRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#FirefightingRole

belongs to
FirefightingRole c
is also defined as
class

FireResistingRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#FireResistingRole

belongs to
FireResistingRole c
is also defined as
class

FireSeparatingRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#FireSeparatingRole

belongs to
FireSeparatingRole c
is also defined as
class

Flatni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Flat

belongs to
Flat c
is also defined as
class

Foyerni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Foyer

belongs to
Foyer c
is disjoint with
Corridor ni, EntranceHall ni, Hall ni, Lobby ni
is also defined as
class

FuelStorageni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#FuelStorage

belongs to
FuelStorage c
is disjoint with
BoilerRoom ni, EngineRoom ni, SwitchGearRoom ni, TransformerRoom ni
is also defined as
class

HabitableRoomni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#HabitableRoom

belongs to
HabitableRoom c
is disjoint with
Auditorium ni, Bathroom ni, CirculationUsage ni, Gallery ni, Kitchen ni, PlaceOfSpecialHazard ni, ServiceUsage ni, Warehouse ni
is also defined as
class

Hallni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Hall

belongs to
Hall c
is disjoint with
Corridor ni, EntranceHall ni, Foyer ni, Lobby ni
is also defined as
class

HallOfResidenceni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#HallOfResidence

belongs to
HallOfResidence c
is also defined as
class

Hospitalni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Hospital

belongs to
Hospital c
is also defined as
class

Hostelni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Hostel

belongs to
Hostel c
is also defined as
class

Hotelni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Hotel

belongs to
Hotel c
is also defined as
class

Impairedni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Impaired

belongs to
Impaired c
is disjoint with
ImpairmentUnknown ni, Operational ni
is also defined as
class

ImpairmentUnknownni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ImpairmentUnknown

belongs to
ImpairmentUnknown c
is disjoint with
Impaired ni, Operational ni
is also defined as
class

InnerRoomRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#InnerRoomRole

belongs to
InnerRoomRole c
is also defined as
class

InstallationNotRequiredni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#InstallationNotRequired

belongs to
InstallationNotRequired c
is disjoint with
InstallationUnknown ni, Installed ni, NotInstalled ni, PartiallyInstalled ni
is also defined as
class

InstallationUnknownni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#InstallationUnknown

belongs to
InstallationUnknown c
is disjoint with
InstallationNotRequired ni, Installed ni, NotInstalled ni, PartiallyInstalled ni
is also defined as
class

Installedni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Installed

belongs to
Installed c
is disjoint with
InstallationNotRequired ni, InstallationUnknown ni, NotInstalled ni, PartiallyInstalled ni
is also defined as
class

Kitchenni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Kitchen

belongs to
Kitchen c
is disjoint with
Auditorium ni, Bathroom ni, CirculationUsage ni, Gallery ni, HabitableRoom ni, PlaceOfSpecialHazard ni, ServiceUsage ni, Warehouse ni
is also defined as
class

Lobbyni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Lobby

belongs to
Lobby c
is disjoint with
Corridor ni, EntranceHall ni, Foyer ni, Hall ni
is also defined as
class

MeansOfEscapeRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#MeansOfEscapeRole

belongs to
MeansOfEscapeRole c
is also defined as
class

NonCompliantResultni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#NonCompliantResult

belongs to
NonCompliantResult c
is disjoint with
CompliantResult ni, UndeterminedResult ni
is also defined as
class

NotApplicableni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#NotApplicable

belongs to
NotApplicable c
is disjoint with
Applicable ni, NotAssessed ni
is also defined as
class

NotAssessedni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#NotAssessed

belongs to
NotAssessed c
is disjoint with
Applicable ni, NotApplicable ni
is also defined as
class

NotInstalledni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#NotInstalled

belongs to
NotInstalled c
is disjoint with
InstallationNotRequired ni, InstallationUnknown ni, Installed ni, PartiallyInstalled ni
is also defined as
class

Officeni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Office

belongs to
Office c
is also defined as
class

Operationalni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Operational

belongs to
Operational c
is disjoint with
Impaired ni, ImpairmentUnknown ni
is also defined as
class

PartiallyInstalledni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PartiallyInstalled

belongs to
PartiallyInstalled c
is disjoint with
InstallationNotRequired ni, InstallationUnknown ni, Installed ni, NotInstalled ni
is also defined as
class

PassiveFireProtectionRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PassiveFireProtectionRole

belongs to
PassiveFireProtectionRole c
is also defined as
class

PlaceOfSpecialHazardni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PlaceOfSpecialHazard

belongs to
PlaceOfSpecialHazard c
is disjoint with
Auditorium ni, Bathroom ni, CirculationUsage ni, Gallery ni, HabitableRoom ni, Kitchen ni, ServiceUsage ni, Warehouse ni
is also defined as
class

PurposeGroup1ani back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup1a

belongs to
PurposeGroup1a c
is also defined as
class

PurposeGroup1bni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup1b

belongs to
PurposeGroup1b c
is also defined as
class

PurposeGroup1cni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup1c

belongs to
PurposeGroup1c c
is also defined as
class

PurposeGroup2ani back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup2a

belongs to
PurposeGroup2a c
is also defined as
class

PurposeGroup2bni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup2b

belongs to
PurposeGroup2b c
is also defined as
class

PurposeGroup3ni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup3

belongs to
PurposeGroup3 c
is also defined as
class

PurposeGroup4ni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup4

belongs to
PurposeGroup4 c
is also defined as
class

PurposeGroup5ni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup5

belongs to
PurposeGroup5 c
is also defined as
class

PurposeGroup6ni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup6

belongs to
PurposeGroup6 c
is also defined as
class

PurposeGroup7ani back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup7a

belongs to
PurposeGroup7a c
is also defined as
class

PurposeGroup7bni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#PurposeGroup7b

belongs to
PurposeGroup7b c
is also defined as
class

ResidentialCollegeni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ResidentialCollege

belongs to
ResidentialCollege c
is also defined as
class

Risk Evaluation Toolni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Risk_Evaluation_Tool

The Building Risk Evaluation Tool (BRET), is intended to provide an easy to follow insight into how the use, design, and construction material choices can influence the resilience of a building to the challenges presented by fire in terms of property protection, business resilience, and insurability. It may provide benefit to designers during the initial development stages looking to ensure the end result will meet the resilience expectations of the occupier and be insurable, and to insurers triaging new prospects.
belongs to
GuidanceDocument c

Schoolni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#School

belongs to
School c
is also defined as
class

ServiceUsageni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ServiceUsage

belongs to
ServiceUsage c
is disjoint with
Auditorium ni, Bathroom ni, CirculationUsage ni, Gallery ni, HabitableRoom ni, Kitchen ni, PlaceOfSpecialHazard ni, Warehouse ni
is also defined as
class

ShelteredHousingni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#ShelteredHousing

belongs to
ShelteredHousing c
is also defined as
class

Shopni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Shop

belongs to
Shop c
is also defined as
class

Storageni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Storage

belongs to
Storage c
is also defined as
class

StoreyExitRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#StoreyExitRole

belongs to
StoreyExitRole c
is also defined as
class

StructuralStabilityPerformanceAspectni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#StructuralStabilityPerformanceAspect

belongs to
StructuralStabilityPerformanceAspect c
is also defined as
class

SwitchGearRoomni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#SwitchGearRoom

belongs to
SwitchGearRoom c
is disjoint with
BoilerRoom ni, EngineRoom ni, FuelStorage ni, TransformerRoom ni
is also defined as
class

TransformerRoomni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#TransformerRoom

belongs to
TransformerRoom c
is disjoint with
BoilerRoom ni, EngineRoom ni, FuelStorage ni, SwitchGearRoom ni
is also defined as
class

UndeterminedResultni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#UndeterminedResult

belongs to
UndeterminedResult c
is disjoint with
CompliantResult ni, NonCompliantResult ni
is also defined as
class

Unknownni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Unknown

belongs to
Unknown c
is disjoint with
Compromised ni, Effective ni
is also defined as
class

UnprotectedAreaRoleni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#UnprotectedAreaRole

belongs to
UnprotectedAreaRole c
is also defined as
class

Warehouseni back to ToC or Named Individual ToC

IRI: https://w3id.org/ficr#Warehouse

belongs to
Warehouse c
is disjoint with
Auditorium ni, Bathroom ni, CirculationUsage ni, Gallery ni, HabitableRoom ni, Kitchen ni, PlaceOfSpecialHazard ni, ServiceUsage ni
is also defined as
class

Legend back to ToC

c: Classes
op: Object Properties
dp: Data Properties
ni: Named Individuals

Acknowledgments back to ToC

The authors would like to thank Silvio Peroni for developing LODE, a Live OWL Documentation Environment, which is used for representing the Cross Referencing Section of this document and Daniel Garijo for developing Widoco, the program used to create the template used in this documentation.